Why does my Side-Power Boating Equipment windlass stop during operation?
- YylongAug 16, 2025
Your Side-Power windlass might stop during operation due to several reasons: * The current limitation has triggered, indicating an overload. Try again with a reduced load; a mechanical failure may be the cause if the windlass is lightly loaded. * The control unit temperature sensor is too warm. Allow the controller to cool down before trying again. * The motor is too hot. The windlass controller calculates motor temperature depending on load and run time; let the windlass cool down. * The internal protection of the controller has triggered, possibly due to excessive surrounding temperature and high load. * A continuous "OUT" or "IN" signal has been active for more than 5 minutes. This is a protection against possible faulty control signals; re-activation is possible.