Siemens 1LA8 - Cooling

Siemens 1LA8
160 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
Item Description Item Description
(4) Type of construction (15) Certificate number
(5) Temperature class (16) Degree of protection
(6) Rated voltage [V] and connections (17) Rotor class
(7) Rated frequency [Hz] (18) Motor weight [kg]
(8) (Content depending on the version) (19) Additional information (optional)
(9) Rated current [A] (20) Maximum speed [rpm]
(10) Rated power [kW] (21) Country of manufacture / City
(11) Power factor [cos φ]
Rotors
The rotor assembly is pressed onto the shaft together with the cage winding. The drive end of
the shaft usually has a cylindrical shaft end. Dependent on the design, a second shaft end
may be located at the non-drive end.
Cooling
The cooling system is designed as a closed, internal cooling circuit. The heat lost from the
machine is dissipated to the ambient air via the machine's surface. A shaft-mounted fan moves
the cooling air in the primary circuit. Movement of the cooling air in the secondary circuit is
driven by a shaft-mounted fan.
Fan
The internal fans are bidirectional.
External fan:
Machines with four poles and more as well as 1L.831.‑2: The external fans are
bidirectional.
Two-pole machines except 1L.831.‑2: The external fans are unidirectional. The
machines have an additional label on the end shield and on the rating plate with an
arrow indicating the direction of rotation.
The 1L.831.‑2 can optionally also be equipped with a unidirectional external fan.
Description
SIMOTICS TN Series N-compact 1LA8
Operating Instructions 08/2017 27

Table of Contents

Other manuals for Siemens 1LA8