EasyManua.ls Logo

Siemens 6SE2101–1AA01 - Message Structure - Control Device to Inverter

Siemens 6SE2101–1AA01
110 pages
Print Icon
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
English7/5
Siemens plc 1993
7.4.2 Message Structure – Control Device to Inverter
15 14 13 12 11 10 9 8 7 6 5 4 3 2 1 0
Data Byte 2 Data Byte 1
Parameter Number
0 = Absolute Frequency
1 = Percentage Frequency
Toggle Bit
Unused
0 0 0 Read Parameter
1 0 0 Write Parameter
0 0 1 Read Current
0 1 0 Read Fault Code
Others unused
15 14 13 12 11 10 9 8 7 6 5 4 3 2 1 0
Data Byte 4 Data Byte 3
Desired Frequency
Absolute 0.0 to 400.0 Hz
Percentage 0.0 to 100.0% of maximum frequency

Table of Contents