8.2 Parameter List
Parameter Description Value Range Default Settings
[ ] – N. America
Only
P00 Frequency, output current or fault code
P01 Low frequency voltage boost 00.0 – 30.0% 00.0
P02 Ramp–up time to maximum frequency 00.0 – 400 s 10.0
P03 Ramp–down time from maximum frequency 00.0 – 400 s 10.0
P04 Frequency control mode selection 000 – 009 000
P05 RUN/STOP mode 000 – 009 000
P06 Voltage to frequency curve selection 000 – 006 000 [001]
P07 Minimum frequency 00.0 – 399 Hz 00.1
P08 Maximum frequency 00.1 – 400 Hz 50.0 [60.0]
P09 Digital frequency set–point adjustment 00.0 – 400 Hz 50.0 [60.0]
P10 Analogue frequency set–point adjustment 080 – 240% 100
P11 DC injection braking 00.0 – 20.0% 00.0
P12 Jog 00.1 – 400 Hz 05.0
P13 Slip compensation 00.0 – 20.0 00.0
P14 Display status / Analogue output 000 – 003 000
P15 Voltage to frequency relationship: knee point 00.1 – 400 Hz 50.0 [60.0]
P16 Voltage to frequency relationship: curve type 000 or 001 000
P17 Current limit 00.1 – rated output 1.1 x
P18 Overload limit 01.0 – 03.0 01.5
P19 Automatic boost 000 – 003 000
P20 Serial interface selection 000 – 003 000
P21 Serial interface address 000 – 030 000
P22 Serial interface parity and baud rate 000 – 008 000
P23 Digital input response speed 000 or 001 000
P24 Fixed frequency mode selection 000 – 002 000
P25 First fixed frequency 00.0 – 400 00.0
P26 Second fixed frequency 00.0 – 400 00.0
P27 Third fixed frequency 00.0 – 400 00.0
P28 Fourth fixed frequency 00.0 – 400 00.0
P29 Skip frequency 00.0 – 400 00.0
P30 Tachometer mode 000 – 004 000
P31 Tachometer scale factor 00.1 – 999 50.0
P32 Feedback compensation: proportional term (%) 000 – 999 050
P33 Feedback compensation: integral term (%) 000 – 250 000
P34 Feedback compensation: differential term (%) 000 – 250 000
P35 Tachometer slip limit (Hz) 00.0 – 20.0 05.0
P36 Tachometer sample rate 001 – 200 001
P37 Display tachometer frequency reading 000 – 400 n/a
P40 Switching frequency select 000 – 002 000 / 002
P41 Parameter default values 000 or 001 000 [001]
P42 Auto reset mode 000 – 002 000
P43 Ramp Smoothing 000 – 100 000
P44 Tachometer Interface Unit 000 – 004 000
P45 Clear Text Operator Panel Language 000 or 001 n/a
P48 Fault code 000 – 011 n/a
P49 Hardware type
P50 Software version
P51 Customer–specific Variants 000 – 255 000
8.3 Fault Codes
Code Meaning
F00 Excessive load current or excessive link voltage. Low line voltage (6SE210*–3AA01 only).
F01 Excessive heatsink temperature.
F02 Corruption of parameterisation data in the non–volatile memory.
F03 Faulty operation of A–D converter or excessive tachometer feedback voltage.
F04 P07 set to a higher value than P08.
F05 P09 outside the limits set by P07 and P08.
F06 Fault on control board.
F07 Value of P25 > P08 setting or < P07 setting.
F08 Value of P26 > P08 setting or < P07 setting.
F09 Value of P27 > P08 setting or < P07 setting.
F10 Value of P28 > P08 setting or < P07 setting.
F11 Inverter tripped externally via X11.4 input.