EasyManua.ls Logo

Siemens 7SK80 - EN100-Module; Description; Setting Notes; Information List

Siemens 7SK80
512 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
Functions
2.1 General
SIPROTEC, 7SK80, Manual
E50417-G1140-C344-A5, Release date 11.2012
58
2.1.7 EN100-Module
2.1.7.1 Description
The EN100-Module enables integration of the 7SK80 in 100-Mbit communication networks in control and au-
tomation systems with the protocols according to IEC 61850 standard. This standard permits uniform commu-
nication of the devices without gateways and protocol converters. Even when installed in heterogeneous envi-
ronments, SIPROTEC 4 relays therefore provide for open and interoperable operation. Parallel to the process
control integration of the device, this interface can also be used for communication with DIGSI and for inter-
relay communication via GOOSE.
2.1.7.2 Setting Notes
IEC 61850 GOOSE Function
The GOOSE function can be disabled via a device parameter. For more information, please refer to Section
2.1.2.2.
2.1.7.3 Information List
No. Information Type of In-
formation
Comments
009.0100 Failure Modul IntSP Failure EN100 Modul
009.0101 Fail Ch1 IntSP Failure EN100 Link Channel 1 (Ch1)
009.0102 Fail Ch2 IntSP Failure EN100 Link Channel 2 (Ch2)

Table of Contents