Installing
3.3 Installing Control Unit
Converter with Control Units CU230P-2; CU240B-2; CU240E-2
Getting Started, 04/2014, A5E32885834B AB
29
Default setting 7: Switch over between fieldbus and jogging using DI 3
All Control Units
Selected with
STARTER: Fieldbus with data set switchover
BOP-2: FB cdS
Factory setting for inverters with PROFIBUS or PROFINET interface
Default setting 8: Motorized
potentiometer (MOP) with safety
function
Control Units CU240E-2
Selected with
STARTER: MOP with Basic Safety
BOP-2: MoP SAFE
PROFIdrive telegram 1
The CU 240B-2 does not have
terminals 16 and 17
Fieldbus interface is not active.
The CU 240B-2 does not have
terminals 16 and 17
Fieldbus interface is not active.
Default setting 9: Motorized
potentiometer (MOP)
All Control Units
Selected with
STARTER: standard I/O with MOP
BOP-2: Std MoP
Default setting 12: Two-wire control
with method 1
All Control Units
Selected with
STARTER: Standard I/O with
analog setpoint
BOP-2: Std ASP
Factory setting for inverters with RS485
interface
Default setting 13: Setpoint via analog
input with safety function
Control Units CU240E-2
Selected with
STARTER: Standard I/O with
analog setpoint and safety
BOP-2: ASPS
Fieldbus interface is not active.
The CU 240B-2 does not have
terminals 16 and 17
Fieldbus interface is not active.
The CU 240B-2 does not have
terminals 16 and 17
Fieldbus interface is not active.