MICROMASTER 440
Operating instructions Issue A1
User Documentation
http://nicontrols.com

Table of Contents

Questions and Answers

  • K
    kellyelizabethJul 26, 2025
    What to do if my Siemens Inverter shows an overvoltage fault?
    • P
      Patrick GarzaJul 27, 2025
      If your Siemens Inverter shows an overvoltage fault, you should reduce the input voltage or check the voltage source.
  • A
    Angela HernandezJul 30, 2025
    What to do if my Siemens Inverter has an overcurrent fault?
    • M
      Melissa MeyerJul 30, 2025
      If you are experiencing an overcurrent fault with your Siemens Inverter, inspect the load conditions and connections.
  • M
    Meghan SuttonAug 4, 2025
    What to do if Siemens MICROMASTER 440 shows undervoltage trip/undervoltage warning?
    • M
      Mrs. Stacey BowmanAug 4, 2025
      If you're getting an undervoltage trip or warning with your Siemens Inverter, ensure the power supply voltage is within the required limits.
  • J
    jmillsAug 8, 2025
    What to do if Siemens Inverter shows fault - motor overtemperature?
    • R
      Robert RiceAug 8, 2025
      If your Siemens Inverter indicates a motor overtemperature fault, allow the motor to cool down and check the ventilation.
  • T
    Thomas DickersonAug 12, 2025
    What to do if Siemens MICROMASTER 440 displays fault - inverter overtemperature?
    • C
      Cindy RhodesAug 13, 2025
      If your Siemens Inverter displays an overtemperature fault, ensure proper cooling and ventilation for the inverter.
  • A
    Anthony Frank MDAug 16, 2025
    What does it mean if both LEDs are flashing at the same time on my Siemens Inverter?
    • M
      Mrs. Brianna Terry PhDAug 17, 2025
      If both LEDs are flashing simultaneously on your Siemens Inverter, indicating a current limit warning, reduce the load to stay within the current limit.
  • K
    kevindownsAug 21, 2025
    What to do if Siemens Inverter is not in ready state and display is >0?
    • A
      Angela WallerAug 21, 2025
      If your Siemens Inverter is not in a ready state and the display shows a value greater than 0, reset the inverter.

Summary

Installation

Mechanical Installation

Provides guidance on physical mounting, drill patterns, and frame sizes.

Electrical Installation

Explains wiring, grounding, and connection procedures for power and control.

Commissioning

Using the MICROMASTER 440

System Parameters

Parameter List (short form)

Lists parameters with their descriptions, default values, and access levels.

Troubleshooting

Troubleshooting with the Status Display Panel

Explains how to interpret inverter status using the LEDs on the SDP.

Troubleshooting with the Basic Operator Panel

Provides troubleshooting steps and checks for motor start/run issues with BOP.

Fault messages

Lists common fault codes, their possible causes, and recommended remedies.

MICROMASTER 440 Specifications

MICROMASTER 440 Performance Ratings

Summarizes the performance ratings, voltage ranges, and capabilities of the inverters.

MICROMASTER 440 Specifications

Details the technical specifications, including dimensions, for different models.

Electro-Magnetic Compatibility (EMC)

Siemens MICROMASTER 440 Series Specifications

General IconGeneral
Power Range0.12 kW to 250 kW
Output Voltage0V to Input Voltage
Frequency Range0 Hz to 650 Hz
Overload Capacity150% for 60 seconds, 200% for 3 seconds
Cooling MethodForced air cooling
Enclosure RatingIP20
Control ModesVector control
Protection FeaturesOvervoltage, undervoltage, short circuit
Communication InterfacesPROFIBUS, CANopen, RS485
Operating Temperature-10°C to +50°C
Input Voltage200 V to 240 V (±10%), 380 V to 480 V (±10%)