13
List of Illustrations
Figure 2-1 Drill pattern for MICROMASTER 440....................................................................................22
Figure 2-2 MICROMASTER 440 Connection Terminals ........................................................................26
Figure 2-3 Motor and Power Connections..............................................................................................27
Figure 2-4 Wiring Guidelines to Minimize the Effects of EMI .................................................................29
Figure 3-1 Inverter block diagram ..........................................................................................................33
Figure 3-2 Panels available for the MICROMASTER 440 Inverter.........................................................34
Figure 3-3 Basic operation with SDP .....................................................................................................36
Figure 3-4 DIP locations on I/O board and the Control Board................................................................36
Figure 3-5 Buttons on the Basic Operator Panel....................................................................................38
Figure 3-6 Changing parameters via the BOP .......................................................................................39
Figure 3-7 Typical Motor Rating Plate Example.....................................................................................41
Figure 5-1 Quick Commissioning Flowchart...........................................................................................51
List of Tables
Table 2-1 Dimensions and Torques of MM440 (all frame sizes)...........................................................23
Table 3-1 Default settings for operation using the Status Display Panel...............................................35
Table 3-2 Default settings for operation using the BOP ........................................................................39
Table 6-1 Inverter conditions indicated by the LEDs on the SDP .........................................................68
Table 7-1 MICROMASTER 440 Performance Ratings .........................................................................78
Table 7-2 Wire Sizes & Terminal Torques – Field Wiring Connectors ..................................................79
Table 7-3 MICROMASTER 440 Specifications.....................................................................................79
Table 9-1 Class 1 - General Industrial ..................................................................................................94
Table 9-2 Class 2 - Filtered Industrial ...................................................................................................94
Table 9-3 Class 3 - Filtered for Residential, Commercial and Light Industry ........................................95
Table 9-4 Compliance Table.................................................................................................................96
http://nicontrols.com

Table of Contents

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Siemens MICROMASTER 440 Series and is the answer not in the manual?

Siemens MICROMASTER 440 Series Specifications

General IconGeneral
Power Range0.12 kW to 250 kW
Output Voltage0V to Input Voltage
Frequency Range0 Hz to 650 Hz
Overload Capacity150% for 60 seconds, 200% for 3 seconds
Cooling MethodForced air cooling
Enclosure RatingIP20
Control ModesVector control
Protection FeaturesOvervoltage, undervoltage, short circuit
Communication InterfacesPROFIBUS, CANopen, RS485
Operating Temperature-10°C to +50°C
Input Voltage200 V to 240 V (±10%), 380 V to 480 V (±10%)