9 Electro-Magnetic Compatibility (EMC) International English
MICROMASTER 440 Operating instructions
92 6SE6400-5CA00-0BP0
9.1 Electro-Magnetic Compatibility (EMC)
All manufacturers / assemblers of electrical apparatus which “performs a complete
intrinsic function and is placed on the market as a single unit intended for the end
user” must comply with the EMC directive EEC/89/336.
There are three routes for the manufacturer/assembler to demonstrate compliance:
9.1.1 Self-Certification
This is a manufacturer's declaration that the European standards applicable to the
electrical environment for which the apparatus is intended have been met. Only
standards that have been officially published in the Official Journal of the European
Community can be cited in the manufacturer's declaration.
9.1.2 Technical Construction File
A technical construction file can be prepared for the apparatus describing its EMC
characteristics. This file must be approved by a ‘Competent Body’ appointed by the
appropriate European government organization. This approach allows the use of
standards that are still in preparation.
9.1.3 EC Type Examination Certificate
This approach is only applicable to radio communication transmitting apparatus. All
MICROMASTER units are certified for compliance with the EMC directive, when
installed in accordance with the recommendations in Section 2.
http://nicontrols.com

Table of Contents

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Siemens MICROMASTER 440 Series and is the answer not in the manual?

Siemens MICROMASTER 440 Series Specifications

General IconGeneral
Power Range0.12 kW to 250 kW
Output Voltage0V to Input Voltage
Frequency Range0 Hz to 650 Hz
Overload Capacity150% for 60 seconds, 200% for 3 seconds
Cooling MethodForced air cooling
Enclosure RatingIP20
Control ModesVector control
Protection FeaturesOvervoltage, undervoltage, short circuit
Communication InterfacesPROFIBUS, CANopen, RS485
Operating Temperature-10°C to +50°C
Input Voltage200 V to 240 V (±10%), 380 V to 480 V (±10%)