Administration
A31003-S2010-M100-10-7619, 27/08/2008
3-22 HiPath 2000/3000/5000 - OpenStage Family, Administration Manual
administration.fm
IP Network Parameters
• Diagnostic community: SNMP community string for the SNMP manager receiving diag-
nostic data.
• QoS traps to QCU: Enables or disables the sending of TRAP messages to the QCU serv-
er.
Value range: "Yes", "No".
Default: "No".
• QCU address: IP address of the QCU server.
• QCU port: Port on which the QCU server is listening for messages.
Default: 12010.
• QCU community: QCU community string.
• QoS to generic destination / QoS to generic device: Enables or disables the sending of
QoS traps to a generic destination.
Value range: "Yes", "No".
Default: "No".
Administration via WBM
System > SNMP