3.5.4 Redundancy
This section controls the switching between main HFA server and standby HFA server.
If Small remote side redundancy is activated, the phone willl switch over to the standby HFA
server in case the connection to the main server ist lost. By default, this is disabled.
When Auto switch back is activated, the phone will switch back to the main server as soon as
the connection is re-established. By default, this is disabled.
Retry count main sets the number of trials to establish a connection to the main server before
the phone switches over to the standby server. The default is 1.
The Timeout main parameter determines the time interval between the last try to get a con-
nection to the main server and the establishing of a connection to the standby server. The de-
fault is 30.
Administration via WBM
Administration via Local Phone
|
--- Admin
|
--- System
|
--- Redundancy
|--- Small remote site
|--- Auto switch back
|--- Retry count main
|--- Timeout main
|--- Retry count standby
|
--- Timeout standby