Fuses
Circuit Fuses for 115
VAC
Fuses for 230 VAC
F1 AC power circuit 1 - Oven heater 2 16 A
(1901693-001)
10
A(1901694-001)
)
)
)
)
)
F5 Medium or low wattage heater channel 6 -
MWH/LWH6
6.3 A
(1901695-001)
6.3 A
(1901695-001)
F2 AC power circuit 2 - Oven heater 1 16 A
(1901693-001)
10
A(1901694-001)
F4 Low wattage heaters 1-5 - LWH1 - LWH5 10
A(1901694-001)
10
A(1901694-001)
F3 Power supply (24 VDC) - FILT AC 3.15 A
(1302004-033)
3.15
A(1302004-033)
CAUTION
Do not substitute fuse values
No substitutes should be used for the fuses noted above. Most of these are sand filled ceramic
fuses with a very fast acting fuse to protect the heater relays. A fuse kit is available, part
number 2020151-001.
3.5.3.2 Modular Oven Model Power Connections
The Maxum Modular Oven can be powered
by an external 24 VDC source or an AC line
with an internal DC power supply. In both
cases the power wiring enters the electron‐
ics enclosure through a cable gland and is
secured at a terminal block.
$&
,QSXW
,QSXW
SXW
'&FDEOHWR3(&0'&
'&
2XWSXW
$&
,QSXW
',1
5DLO
Power Supply Connections
Installation Steps
3.5 Cable Connections
Installation Manual
Installation Manual, 12/2019, 2000595 Rev 1 23