Requirements for operation
2.5 Configuration example: Server systems
eP-Satellite server
26 Operating Instructions, 06/2009
2.5 Configuration example: Server systems
Scope of functions
The tables below show an example of an eP-Satellite system's hardware configuration and
full scope of functions.
The exact service specifications for the servers mentioned above will depend on how eP-
Satellite is to be used (e.g. number of machines logged on, number of monitored states,
number of saved events); therefore, the tables have been provided solely as a guide. eP-
Satellite users define their own specific requirements for the servers used as appropriate for
their own environments.
eP-Satellite External Web Server
Component Number/Type
Processor 1 x Intel dual-core, 3 GHz
Memory 2 GB RAM
HDD memory OS 2 x 73 GB, 10,000 rpm (RAID1)
HDD memory log files 2 x 73 GB, 10,000 rpm (RAID1)
Internal eP-Satellite web server
Component Number/Type
Processor 1 x Intel dual-core, 3 GHz
Memory 2 GB RAM
HDD memory OS 2 x 73 GB, 10,000 rpm (RAID1)
HDD memory log files 2 x 73 GB, 10,000 rpm (RAID1)
eP-Satellite database server
Component Number/Type
Processor 1 x Intel dual-core, 3 GHz
Memory 4 GB RAM
HDD memory OS 2 x 73 GB, 10,000 rpm (RAID1)
SQL transaction logs 2 x 73 GB, 10,000 rpm (RAID1)
HDD memory SQL data 4 x 200 GB, 10,000 rpm (RAID10)

Table of Contents

Other manuals for Siemens MCP 398C

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Siemens MCP 398C and is the answer not in the manual?

Siemens MCP 398C Specifications

General IconGeneral
BrandSiemens
ModelMCP 398C
CategoryControl Systems
LanguageEnglish

Related product manuals