Release management - Updating the eP-Satellite server
5.4 BC run of version 4.7.0 on version 4.7.1
eP-Satellite server
Operating Instructions, 06/2009
93
Switching IIS offline
You must also ensure that the system cannot be accessed by external parties while the
Business Converter is running offline. To do this, first create a backup of the settings in the
IIS Manager. Following this, activate "Denied access" under "Directory Security" → "IP
address and domain name restrictions" on the default website, and add address 127.0.0.1 as
an exception.
Calling the Business Converter
The Business Converter must be run in the prompt. To do this, switch to path
\build\output\server\utils\release\bin in the unzipped installation package and run file
ePS.Business.Converter.exe as described below.
Business Converter: Starting offline
Command line:
ePS.Business.Converter.exe /TEMPORARILYUNLOCKORGANIZATIONS
/MAINTENANCETICKETTEMPLATETRIGGER /REPAIRNCVMACCEPTMINDATE
/WebDir:"c:\eps_services\Services\Version4\ba" >> C:\temp\bcoffline.log 2>&1
If this run has been successful, the next Business Converter can be started:
Command line:
ePS.Business.Converter.exe /DELETEWRONGVARMONCOMPVALUES
/WebDir:"c:\eps_services\Services\Version4\ba" >> C:\temp\bcdeletewrong.log 2>&1
Switching IIS online
Once the Business Converter has finished running offline, the system is switched back
online and can, therefore, be accessed again. For this purpose, the backup made in the
section titled "Switching IIS offline" is restored.

Table of Contents

Other manuals for Siemens MCP 398C

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Siemens MCP 398C and is the answer not in the manual?

Siemens MCP 398C Specifications

General IconGeneral
BrandSiemens
ModelMCP 398C
CategoryControl Systems
LanguageEnglish

Related product manuals