MICROMASTER 420/430/440, Getting Started Guide 10/14 - A5E02779537A3 19
Input voltage range 3 AC 500 V – 600 V ± 10 % (Unfiltered)
Order No. 6SE6440- 2UE17
-5CA1
2UE21
-5CA1
2UE22
-2CA1
2UE24
-0CA1
2UE25
-5CA1
2UE27
-5CA1
2UE31
-1CA1
2UE31
-5DA1
Fuse [A]
10 10 10 16 16 25 32 35
Recommended 3N
3803-6 3803-6 3803-6 3805-6 3805-6 3810-6 3812-6 3814-6
for UL specified 3NE
*
*
* * * * * 1803-0
Input Cable Min.
[mm
]
1.0 1.0 1.0 1.5 1.5 2.5 4.0 6.0
[awg]
18 18 18 16 16 14 12 10
Input Cable Max.
[mm
]
10.0 10.0 10.0 10.0 10.0 10.0 10.0 35.0
[awg]
8 8 8 8 8 8 8 2
Output Cable Min.
[mm
]
1.0 1.0 1.0 1.0 1.0 2.5 4.0 4.0
[awg]
18 18 18 18 18 14 12 12
Output Cable Max.
[mm
]
10.0 10.0 10.0 10.0 10.0 10.0 10.0 35.0
[awg]
8 8 8 8 8 8 8 2
Order No. 6SE6440- 2UE31
-8DA1
2UE32
-2DA1
2UE33
-0EA1
2UE33
-7EA1
2UE34
-5FA1
2UE35
-5FA1
2UE37
-5FA1
Fuse [A]
50 63 80 80 125 160 160
Recommended 3N
3820-6 3822-6 3824-6 3824-6 3132-6 3136-6 3136-6
for UL specified 3NE
1817-0 1818-0 1820-0 1820-0 1022-0 1224-0 1224-0
Input Cable Min.
[mm
]
10.0 10.0 16.0 25.0 25.0 50.0 50.0
[awg]
8 8 6 3 3 1/0 1/0
Input Cable Max.
[mm
]
35.0 35.0 35.0 35.0 150.0 150.0 150.0
[awg]
2 2 2 2 300 300 300
Output Cable
Min.
[mm
]
6.0 10.0 16.0 16.0 25.0 35.0 50.0
[awg]
10 8 6 6 3 2 1/0
Output Cable
Max.
[mm
]
35.0 35.0 35.0 35.0 150.0 150.0 150.0
[awg]
2 2 2 2 300 300 300
*UL listed fuses, such as those stated in the warnings on page 2 are required for use in America.
*UL-gelistete Sicherungen, wie in den Warnhinweisen auf Seite 2 angegeben, sind für den Einsatz in Amerika vorgeschrieben.
*Des fusibles homologués UL, tels que ceux mentionnés dans les avertissements à la page 2 sont requis pour une utilisation en Amérique.
*I fusibili omologati UL, come quelli indicati nelle avvertenze a pagina 2, sono richiesti per l'utilizzo sul territorio americano.
*Para uso en Norteamérica se requieren fusibles conformes a UL, como los que figuran en las advertencias de la página 2.