12 MICROMASTER 420/430/440, Getting Started Guide 10/14 - A5E02779537A3
Input voltage range 3 AC 200 V
240 V, ± 10 % (Unfiltered)
Order No. 6SE6420- 2UC11-
2AA1
2UC12-
5AA1
2UC13-
7AA1
2UC15-
5AA1
2UC17-
5AA1
2UC21-
1BA1
2UC21-
5BA1
2UC22-
2BA1
Fuse [A] 10 10 10 10 10 16 16 20
Recommended 3NA 3803 3803 3803 3803 3803 3805 3805 3807
For UL specified * * * * * * * *
Input Cable, min.
[mm
] 1.0 1.0 1.0 1.0 1.0 1.0 1.0 1.0
[awg] 18 18 18 18 18 18 18 18
Input Cable, max.
[mm
] 2.5 2.5 2.5 2.5 2.5 6.0 6.0 6.0
[awg] 14 14 14 14 14 10 10 10
Output Cable, min.
[mm
] 1.0 1.0 1.0 1.0 1.0 1.0 1.0 1.0
[awg] 18 18 18 18 18 18 18 18
Output Cable, max.
[mm
] 2.5 2.5 2.5 2.5 2.5 6.0 6.0 6.0
[awg] 14 14 14 14 14 10 10 10
Order No. 6SE6420- 2UC23-
0CA1
2UC24-
0CA1
2UC25-
5CA1
Fuse [A] 25 32 35
Recommended 3NA
3810 3812 3814
For UL specified * * *
Input Cable, min.
[mm
] 2.5 2.5 4.0
[awg] 14 14 12
Input Cable, max.
[mm
] 10.0 10.0 10.0
[awg] 8 8 8
Output Cable, min.
[mm
] 1.5 2.5 4.0
[awg] 16 14 12
Output Cable, max.
[mm
] 10.0 10.0 10.0
[awg] 8 8 8
Input voltage range 3 AC 380 V – 480 V, ± 10 % (with built in Class A Filter)
Order No. 6SE6420- 2AD22-
2BA1
2AD23-
0BA1
2AD24-
0BA1
2AD25-
5CA1
2AD27-
5CA1
2AD31-
1CA1
Fuse [A] 16 16 20 20 25 35
Recommended 3NA 3805 3805 3807 3807 3810 3814
For UL specified * * * * * *
Input Cable, min.
[mm
] 1.0 1.0 1.5 2.5 4.0 6.0
[awg] 18 18 16 14 12 10
Input Cable, max.
[mm
] 6.0 6.0 6.0 10.0 10.0 10.0
[awg] 10 10 10 8 8 8
Output Cable, min.
[mm
] 1.0 1.0 1.0 1.5 2.5 4.0
[awg] 18 18 18 16 14 12
Output Cable, max.
[mm
] 6.0 6.0 6.0 10.0 10.0 10.0
[awg] 10 10 10 8 8 8