Connectable components
9.2 PP 72/48D PN
NCU 7x0.3 PN
Manual, 09/2011, 6FC5397-1EP40-0BA0
101
Supply system lines
Table 9- 15 Cable specification at X1
Characteristics Version
Connection option Up to 2.5 mm
2
Current carrying capacity max. 10 A
Max. cable length 10 m
Use flexible cables with a cross-section of 0.25 to 2.5 mm
2
(or AWG 23 to AWG 13) for
wiring the power supply according to the maximum current that flows.
If you only use one wire per connection, an end sleeve is not required.
You can use end sleeves without an insulating collar in accordance with DIN 46228, Form A
long version.
9.2.3.3 X2 PROFINET
Data Transmission Rate and Cables
For PROFINET, you require a data transmission rate of 100 Mbit/s (Fast Ethernet). The
interfaces are designed for full-duplex mode; in other words, the ports can both transmit and
receive. For data transfer purposes you can use electrical twisted copper cables (twisted
pair, 4-wire, 100Base-T):
The transmission characteristics of these cables must meet the requirements of CAT5.
The maximum length of the connections between the end device and network component
or between two network components (e.g. switch ports) must not exceed 100 m.
Pin assignment
Table 9- 16 PROFINET interfaces X2, ports 1, 2
Pin Signal name Signal type Meaning
1 TX+ O Transmit data +
2 TX- O Transmit data -
3 RX+ I Receive data +
4 N.C. - Reserved, do not use
5 N.C. - Reserved, do not use
6 RX- I Receive data -
7 N.C. - Reserved, do not use
8 N.C. - Reserved, do not use