Connectable components
9.1 NX10.3 / NX15.3
NCU 7x0.3 PN
88 Manual, 09/2011, 6FC5397-1EP40-0BA0
9.1.4 Connection
Power supply X124
Table 9- 2 Pin assignment for X124
Terminal Function
+
+
24 V DC power supply (20.4 V - 28.8 V)
M
M
Ground
Note
The two "+" and "M" terminals are jumpered in the connector and not in the device. This
ensures that the supply voltage is looped through.
The current consumption increases by the current consumption of DRIVE-CLiQ and the
digital outputs.
When using external power supplies (e.g. SITOP), the ground potential must be connected
with the protective ground terminal (PELV).
Table 9- 3 Cable specification for X124
Characteristics Version
Connector type Screw-type terminals
Connection option Up to 2.5 mm
2
Max. current carrying capacity incl. loop-through 20 A
Maximum power consumption 0.8 A (without load)
Max. cable length 10 m