EasyManua.ls Logo

Siemens NCU 7x0.3 PN Series - Analog X3 Inputs;Outputs

Siemens NCU 7x0.3 PN Series
171 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
Connectable components
9.3 PP 72/48D 2/2A PN
NCU 7x0.3 PN
Manual, 09/2011, 6FC5397-1EP40-0BA0
131
Technical data:
Table 9- 46 Electrical specification of the digital outputs
Digital outputs min. Standard max. nominal
High-level voltage (U
H
) V
CC
- 3 V
1)
V
CC
24 V
Output current I
OUT
- - 250 mA
2)
-
Voltage with low level (U
L
) - - - Output open
Leakage current at low level - 50 μA 400 μA -
Signal delay time T
PHL
- 0.5 ms - -
Maximum switching frequency
Resistive load - - 100 Hz -
Inductive load - - 2 Hz -
Lamp - - 11 Hz -
1)
U
H_typical
= V
CC
- I
OUT
× R
ON
V
CC
: Current operating voltage
I
OUT
: Output current
Maximum short-circuit current: 4 A (max. 100 μs, V
CC
= 24 V)
R
ON
: Maximum internal resistance = 0.4 Ω
2)
Where demand factor is 100% (all outputs active)
Incorrect connection causes neither high level nor destruction of the outputs.
9.3.4.5 Analog X3 inputs/outputs
Cable specification
Connectors: 12-pin socket/plug combination
Cable: shielded
max. cable length: 30 m
max. connectable core cross-section: 0.5 mm
2