Connecting
7.9 Digital inputs/outputs
NCU 7x0.3 PN
74 Manual, 09/2011, 6FC5397-1EP40-0BA0
Using a shield connection
1. Remove the fixing bracket of the shield connection.
2. Insert the cable and fasten the fixing bracket.
① Fixing bracket of the shield connection
② Torx screw M3/0.8 Nm
Figure 7-13 Shield support
7.9.4 Technical data
Digital inputs on X122/X132
Table 7- 28 Technical data of digital inputs X122/X132
Parameters Values
Voltage -30 V to +30 V DC
Typical current consumption 9 mA at 24 V DC
Galvanic isolation Reference potential is terminal G1 or G2
High signal level: 15 V to 30 V Signal level (including ripple)
Low signal level: -3 V to 5 V
L → H: 50 μs Signal propagation times, typical
H → L: 100 μs