Connectable components
9.3 PP 72/48D 2/2A PN
NCU 7x0.3 PN
124 Manual, 09/2011, 6FC5397-1EP40-0BA0
Default device names
The switch positions 1 to 8 define the default device name of the I/O module.
There are up to 128 default device names. If these default device names are used, there is
no need for initialization.
Note
The default device names cannot be reconfigured using the STEP7 "device initialization"
facility for example.
If you are connecting the I/O module to a SINUMERIK controller as a PROFINET
component, make sure that this functionality is supported by the controller concerned.
Table 9- 41 Default device name with switch S1
1 2 3 4 5 6 7 8 9 10 Default device name
on on on on on on on off pp72x48pn127
off on on on on on on off pp72x48pn126
on off on on on on on off pp72x48pn125
off off on on on on on off pp72x48pn124
on on off on on on on off pp72x48pn123
off on off on on on on off pp72x48pn122
on off off on on on on off pp72x48pn121
off off off on on on on off pp72x48pn120
on on on off on on on off pp72x48pn119
off on on off on on on off pp72x48pn118
on off on off on on on off pp72x48pn117
off off on off on on on off pp72x48pn116
on on off off on on on off pp72x48pn115
off on off off on on on off pp72x48pn114
on off off off on on on off pp72x48pn113
off off off off on on on off pp72x48pn112
x x x x x x x x "
on on on on off off off off pp72x48pn15
off on on on off off off off pp72x48pn14
on off on on off off off off pp72x48pn13
off off on on off off off off pp72x48pn12
on on off on off off off off pp72x48pn11
off on off on off off off off pp72x48pn10
on off off on off off off off pp72x48pn9
off off off on off off off off pp72x48pn8