Connectable components
9.3 PP 72/48D 2/2A PN
NCU 7x0.3 PN
144 Manual, 09/2011, 6FC5397-1EP40-0BA0
Table 9- 64 Measured values and responses in the temperature measurement operating mode
Pt100
Address
Incorrect operating mode Resistor is not connected
Operating mode QB72 16#AA 16#0F
Format QB73 16#1 16#1
Value QW76 - -
Value QW78 - -
Operating mode IB72 16#AA 16#0F
Format IB73 16#81 16#81
Value IW76 - -
Value IW78 - -
IB50 16#2 16#2 Diagnostics
IB51 16#3 16#6
PNFault LED on on
Troubleshooting Deactivating/activating Deactivating/activating