Accessories
7.1 Reactor and filter
PM250 Power Module
62 Hardware Installation Manual, 09/2012, A5E01003502B AD
7.1.3 Sine-wave filter
Installing the sine-wave filter as base component
The sine-wave filters for Power Modules with a rated power (HO) up to 11 kW are designed
as base components. The sine-wave filter is attached to the mounting surface and the Power
Module is mounted directly on the sine-wave filter. The cables to the Power Module are
already connected to the sine-wave filter. The sine-wave filter is connected to the motor
through terminals.
0
0RWRU
/LQH
0RXQ
WLQJ
VXUIDFHRU
FDELQHWZDOO
&RQQHFWLRQ
FDEOH
6LQHZDYH
ILOWHU
3RZHU0RGXOH
8
9
:
3(
8
9
:
3(
8
9
:
3(
Figure 7-6 Connecting the sine-wave filter as base component
The overall and mounting dimensions of the sine-wave filter are written in the technical
specifications.