88 | Part 3
■ M00 PROGRAM STOP
Function
By this command, machine state changes as follows.
- Automatic Operation stops temporarily (HOLD) under the state of Cycle Start
Switch ON
- Spindle, Coolant and Air Blow stop
- Manual Clamp/Unclamp are possible
- After changing manual mode, spindle turning command is possible.
■ M01 OPTIONAL STOP
Function
By this command, machine state changes as follows.
- Automatic Operation stops temporarily (HOLD) under the state of Cycle Start
Switch ON
- Spindle, Coolant and Air Blow stop
- Manual Clamp/Unclamp are possible
- After changing manual mode, spindle turning command is possible.
Condition of Command
This command is Valid when optional stop is "ON".
M01 is commanded when Optional Stop is "ON", automatic operation stops and Cycle
Start Lamp keeps "ON". Changing mode into Manual, whole manual operations are
possible. If M01 is commanded during operation of spindle or coolant, the operations
will stop. When Cycle Start again, In order to resume Cycle Start, change mode to
AUTO and press Cycle Start Switch.
* Caution)
After spindle stopped by M01, Clamp/Unclamp of chuck is possible using Foot
Switch only without mode change.
■ M02 PROGRAM END
Function
End Program and reset CNC.
M02/30 LED are ON. Its LED will be OFF when the mode changes into Manual Mode
or automatic operation is to be executed.
If M02 is commanded, program will be stopped and CNC reset.