Chapter 2
Installing the Device
RUGGEDCOM RX1501
Installation Guide
18 Connecting Low DC Power
Figure14:Assembling the Safety Cover
1.Screw 2.Safety Cover 3.Screw Terminal Block 4.RUGGEDCOM RX1501 Device
5. Using a braided wire or other appropriate grounding wire, connect the ground terminal to the chassis
ground connection. The surge ground terminal is used as the ground conductor for all surge and transient
suppression circuitry internal to the unit.
6. Using a #10 ring lug and #10-32 screw, secure the ground terminal on the power source to the chassis
ground terminal on the device. Make sure the lug is tightened to 1.1 N·m (9.5 lbf·in).