EasyManua.ls Logo

Siemens RUGGEDCOM RX1510 - Connecting Low DC Power

Siemens RUGGEDCOM RX1510
52 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
RUGGEDCOM RX1510
Installation Guide
Chapter 2
Installing the Device
Connecting Low DC Power 13
Section2.6.2
Connecting Low DC Power
To connect a low DC power supply to the device, do the following:
CAUTION!
Electrical hazard – risk of damage to equipment. Do not connect AC power cables to a 12, 24 or 48 VDC
power supply terminal block. Damage to the power supply may occur.
IMPORTANT!
When connecting the device to a DC power source, make sure the source provides only positive voltage.
NOTE
The screw-type terminal block is installed using Phillips screws and compression plates, allowing either
bare wire connections or crimped terminal lugs. Use #6 size ring lugs for secure, reliable connections.
1. Connect the power supply terminal block to the device.
4
5
3
1
Figure8:DC Terminal Block Wiring – Pluggable Terminal Block for 12P, 24P and 48P Power Supplies
1.3-Position Terminal Block 2.Positive (+) Terminal 3.Negative (-) Terminal 4.Ground Terminal