Chapter 6
Certification
RUGGEDCOM RX1510
Installation Guide
42 EMC and Environmental Type Tests
Description Test Levels
Earth ground ports
Signal ports 2.5 kV common mode @1MHz
DC Power Ports
Oscillatory
AC Power Ports
2.5 kV common
1 kV differential mode @ 1 MHz
Radiated RFI Enclosure ports 35 V/m
Enclosure Contact ± 8 kVESD
Enclosure Air ± 15 kV
Environmental Type Tests
Test Description Test Levels
Severity
Levels
IEC 60068-2-1 Cold Temperature Test Ad -40 °C (-40 °F), 16 Hours
IEC 60068-2-2 Dry Heat Test Bd 85 °C (185 °F), 16 Hours
IEC 60068-2-30 Humidity (Damp Heat, Cyclic) Test Db 95% (non-condensing),
55 °C (131 °F), 6 cycles
IEC 60255-21-1 Vibration 2 g @ 10-150 Hz Class 2
Shock 30 g @ 11 ms Class 2IEC 60255-21-2
Bump 10 g @ 16 ms Class 1
Long Life (Random Vibration)IEC 61373
Shock
Category 1 Class B
IEC 60255-21-3 Seismic Method A Level 2
MIL-STD-810G Altitude 12192 m (40000 ft)
@ 40 °C, 90 minutes