11-2 Siemens PM240-2_EN_rev00-30082019.docx
At this point the system is ready to be used and configured.
Any additional tune-up can be done by acting directly on the values of the parameters of the Drive available
in the list "User" or BOP , as explained in detail in paragraph 11.4 .
ATTENTION: Only in case of change of the inverter or of the electric motor, you must do motor
recognition by P1910, before performing any calibration. Please contact OMARLIFT Service, for the
procedure.
11.3 PARAMETERS LIST
Below are listed the parameters of the list "User " and their default values:
After the modify of the parameters of interest, it is always necessary to save the new values on
the hard memory of the Control Unit (with button RAM to ROM), in order to prevent a loss of data at the
first shut down (voluntary or accidental). Using WEBSERVER software, you have to switch ONLINE, then
press the push button RAM to ROM . Alternatively, see the procedure described to the chapter 10 for the
setup by BOP.
Table 16 List of parameters
SETTING UPWARDS DIRECTION - CONFIGURAZIONE SALITA
Inspection Speed UP (2.2.9)
Releveling speed UP (2.2.8)
SETTING DOWNWARDS DIRECTION - CONFIGURAZIONE DISCESA
Pre-Start Speed value 2 (2.3.2.2)
Pre-Start Time value 2 (2.3.3.2)
Pre-Start Delay Additional value 2 (2.3.3D.2)
Final Dec Time value 2 (2.3.14.2)
Inspection Speed DOWN (2.3.9)
Releveling speed DOWN (2.3.8)
Plus Speed while EDV closing
RUPTURE VALVE TEST- TEST VALVOLA PARACADUTE
Parachute function (2.13.1)
Ramp-up time (ms) (2.13.3)
Ramp-down time (ms) (2.13.5)
Parachute Max.Speed TimeOut (2.13.4)
EMERGENCY MODE - MODALITÀ EMERGENZA
Emergency Speed Up (2.6.1)
Emergency Speed Down (2.6.2)
SHORT FLOOR - PIANO CORTO