EasyManua.ls Logo

Siemens S120 PM240-2 - Configuration Parameters

Siemens S120 PM240-2
70 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
Siemens PM240-2_EN_rev00-30082019.docx 11-3
p21530
Short Floor activate
0
1
0
p21548
Short Floor Speed Up (2.14.2)
0.160
%
0.800
0.200
p21549
Short Floor Speed Down (2.14.3)
-0.110
%
-0.800
-0.200
p21651
Short Floor Ramp Factor
1.000
NA
NA
COMPENSATIONS COMPENSAZIONI
p21570
Switch tipologia olio
0
NA
NA
p21571
P.X1
0.900
4.000
0.000
p21572
P.X2
0.800
4.000
0.000
p21573
P.X3
0.200
4.000
0.000
p21574
P.X4
0.300
4.000
0.000
p21575
P.X5
0.250
4.000
0.000
p21576
P.X6
0.200
4.000
0.000
p21577
P.X7
1.000
4.000
0.000
p21578
P.X8
1.600
4.000
0.000
p21579
P.X9
1.000
4.000
0.000
p21580
P.X10
0.200
4.000
0.000
p21581
P.X11
2.900
4.000
0.000
p21582
P.X12
1.000
4.000
0.000
AUTOTUNING - AUTO REGOLAZIONE
p21600
Torque Measure without load
0
1
0
p21601
Torque Measure with full load
0
1
0
TORQUE VALUES - VALORI COPPIA
p21590
Ascending Torque Min Value
29.731
Nm
NA
NA
p21591
Ascending Torque Max Value
51.892
Nm
NA
NA
p21592
Ascending Comp Value
0.030
%
NA
NA
p21595
Descending Torque Min Value
-8.194
Nm
NA
NA
p21596
Descending Torque Max Value
9.558
Nm
NA
NA
p21597
Descending Comp Value
0.035
%
NA
NA
NOTE: (*) all speeds are expressed in rpm% compared to the rated motor speed (usually 3000 r/min)
11.4 CONFIGURATION PARAMETERS
For both directions, it is necessary to adjust some values to your system:
Set the desired value for the high-speed P21507 (2.2.6) (P21537 (2.3.6) for downward).
Set the desired value for the low speed P21512 (2.2.7) (P21542 (2.3.7) for the downward).
Set the desired value for the inspection speed P21514 (2.2.9) (P21544 (2.3.9) for the downward
direction).