EasyManua.ls Logo

Siemens SINAMICS V60 User Manual

Siemens SINAMICS V60
40 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
Page #1 background imageLoading...
Page #1 background image
© Siemens AG 2010 - 2014. All rights reserved
A5E03975175-002, 04/2014
1
SINAMICS
V60
Controlled Power Module (CPM60.1)
Getting Started
Legal information
Warning notice system
This manual contains notices you have to observe in order to ensure your personal safety, as well as to prevent damage to property. The
notices referring to your personal safety are highlighted in the manual by a safety alert symbol, notices referring only to property damage
have no safety alert symbol. These notices shown below are graded according to the degree of danger.
DANGER
indicates that death or severe personal injury
will
result if proper precautions are not taken.
WARNING
indicates that death or severe personal injury
may
result if proper precautions are not taken.
CAUTION
indicates that minor personal injury can result if proper precautions are not taken.
NOTICE
indicates that property damage can result if proper precautions are not taken.
If more than one degree of danger is present, the warning notice representing the highest degree of danger will be used. A notice warning of
injury to persons with a safety alert symbol may also include a warning relating to property damage.
Qualified Personnel
The product/system described in this documentation may be operated only by
personnel qualified
for the specific task in accordance with
the relevant documentation, in particular its warning notices and safety instructions. Qualified personnel are those who, based on their
training and experience, are capable of identifying risks and avoiding potential hazards when working with these products/systems.
Proper use of Siemens products
Note the following:
WARNING
Siemens products may only be used for the applications described in the catalog and in the relevant technical documentation. If products
and components from other manufacturers are used, these must be recommended or approved by Siemens. Proper transport, storage,
installation, assembly, commissioning, operation and maintenance are required to ensure that the products operate safely and without any
problems. The permissible ambient conditions must be complied with. The information in the relevant documentation must be observed.

Other manuals for Siemens SINAMICS V60

Question and Answer IconNeed help?

Do you have a question about the Siemens SINAMICS V60 and is the answer not in the manual?

Siemens SINAMICS V60 Specifications

General IconGeneral
BrandSiemens
ModelSINAMICS V60
CategoryControl Unit
LanguageEnglish

Summary

Legal Information

Warning Notice System

Describes the warning notice system, grading danger degrees, and safety alert symbols.

Qualified Personnel

Defines qualified personnel required for operating the product/system safely.

Proper Use of Siemens Products

Outlines guidelines for the correct application, transport, storage, installation, and operation.

Preface

General Information

System Overview

Describes the SINAMICS V60 servo drive system and its connection to CNC controllers.

Safety Notes

Details critical safety precautions for operation, transport, storage, and installation.

Component Identification

Lists components included in the drive unit and motor unit packages.

Technical Data

Provides detailed technical specifications including current, power, torque, and environmental data.

Installation

Mechanical Installation

Covers drive mounting, clearance requirements, and the use of supplied cable clamps.

Motor Mounting

Details motor mounting dimensions and considerations for different motor variants.

Electrical Installation

Explains system connections to SINUMERIK 808D CNC controllers and SIMATIC PLCs.

Interface Definitions

Describes various interfaces for line supply, motor output, brake, and DC power supply.

Signal Sequence Examples

Illustrates power-on and power-off sequences with timing diagrams.

Commissioning

Displays and Settings

Covers main menu navigation, status displays, and parameter settings.

Function Menu

Explains navigation and operations within the function menu, including JOG and parameter saving.

Setpoints from NC

Details how to configure setpoints like encoder resolution from the NC.

First Commissioning Procedure

Provides a step-by-step flowchart for the initial setup of the drive and motor.

System Commissioning Procedure

Outlines the process for overall system integration and testing with the CNC controller.

Parameter List

Describes the function, range, default values, and effect of various parameters.

Display Data List

Lists available data for display, their formats, units, and data groups.

Troubleshooting

LED Status Indicators

Explains the meaning of drive status LEDs (RDY/JOG, ERR) and 7-segment display.

Alarm Overview

Lists alarm codes, their causes, remedies, and acknowledgement methods.

Drive Self-Test Errors

Details error codes displayed during the drive's automatic self-test upon power-on.

Other Common Faults

Describes faults related to brake operation, axis movement, and signal connections.

Appendix

Order Numbers

Lists part numbers for SINAMICS V60 drives, 1FL5 servo motors, and cables.

Technical Support

Provides contact information for Siemens technical support via telephone and internet.