Controlled Power Module (CPM60.1)
18 A5E03975175-002, 04/2014
2.3
Interface definition
Line supply connection L1, L2, L3
Interface
Signal name
Description
L1 Line phase L1
L2 Line phase L2
L3 Line phase L3
Maximum conductor cross-section: 2.5 mm
2
Motor output connection U, V, W
Interface
Signal name
Description
Schematic connection diagram
U Motor phase U
V Motor phase V
W Motor phase W
Maximum conductor cross-section: 2.5 mm
2
Motor brake connection X3
Interface
Signal name
Description
Schematic connection diagram
B+ + 24 V, motor brake
voltage positive
B- 0 V, motor brake voltage
negative
Maximum conductor cross-section: 1.5 mm
2
DC 24 V power supply connection X4
Interface
Signal name
Description
Remark
24 V DC 24 V Voltage 24 V DC
(20.4 - 28.8 V)
Current consumption:
Max. 0.8 A without brake
power supply
Max. 1.4 A with brake power
supply
0 V 0 V
PE Protective earth - -
Maximum conductor cross-section: 1.5 mm
2