Product Characteristics
4.5 SCALANCE X204-2
0 – 85 m
0 -3,000 m
IE FC marine/trailing cable with IE FC RJ-45 plug
180
or
IE FC marine/trailing cable (0 - 75 m) + 10 m TP
cord
Glass FOC
62.5/125 µm or 50/125 µm glass fiber;
≤ 1 dB/km at 1300 nm;
600 MHz x km;
6 dB max. permitted FO cable attenuation with 3
dB link power margin
Aging time
Aging time 5 minutes
Permitted Environmental Conditions / EMC
Operating temperature 0° C through +60° C
Storage/transport temperature -40° C through +80° C
Relative humidity in operation ‹ 95% (no condensation)
Operating altitude 2000 m at max 56 °C ambient temperature
3000 m at max. 50 °C ambient temperature
RF interference level EN 50081-2 Class A
Noise immunity EN 50082-2
Degree of protection Tested to IP30
Approvals
UL 60950 c-UL-us
CSA C22.2 No. 60950
c-Ul-us for hazardous locations UL 1604, UL 2279Pt.15
FM FM 3611
C-TICK AS/NZS 2064 (Class A).
CE EN 50081-2, EN 50082-2
ATEX Zone 2 EN50021
MTBF
MTBF 37.56 years
Construction
Dimensions (W x H x D) in mm 60 x 125 x 124
Weight in g 780
Installation options DIN rail
S7-300 standard rail
Wall Mounting
Order Numbers
SCALANCE X204-2 6GK5204-2BB00-2AA3
"Industrial Ethernet TP and Fiber Optic Networks"
manual
6GK1970-1BA10-0AA0
IE FC Stripping Tool 6GK1901-1GA00
Industrial Ethernet SCALANCE X-100 and SCALANCE X-200 Product Line