EasyManua.ls Logo

Siemens SCALANCE X-100 - The Agent Trap Configuration WBM Menu

Siemens SCALANCE X-100
121 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
Diagnostics over Industrial Ethernet
6.2 Web Based Management (WBM)
Displays the user name for write access to SNMP variables. Here, changes can only be
made, when write protection (SNMP read only) has been disabled.
6.2.4.16 The "Agent Trap Configuration" WBM Menu
Agent Trap Configuration - SNMP Traps for Alarm Events
If an alarm event occurs, the SCALANCE X-200 can send traps (alarm frames) to up to two
different (network management) stations at the same time. Traps are sent only for events
specified in the Agent Event Configuration menu.
Figure 6-21 "Agent Trap Configuration" Dialog
IP Address Text Boxes
Here, you enter the addresses of the stations to which the SCALANCE X‑200 will send traps.
Enable Trap Check Box
Click on the check box next to the IP addresses to enable the sending of traps to the
corresponding stations.
Industrial Ethernet SCALANCE X-100 and SCALANCE X-200 Product Line
Commissioning Manual, 1,
6-25