Diagnostics over Industrial Ethernet
6.2 Web Based Management (WBM)
Figure 6-17 "Agent Configuration" Dialog
IP Address Text Box
The IP address of the SCALANCE X-200. If you make a change here, the WBM loses the
connection to the SCALANCE X-200. Enter the new address in the Internet browser to
reestablish the connection.
Subnet Mask Text Box
Here, you enter the subnet mask of the SCALANCE X-200.
Default Gateway Text Box
If the PC with the Internet browser is not in the same subnet as the SCALANCE X-200, you
must enter the IP address of the default gateway here.
6.2.4.13 The "Agent Event Configuration" WBM Menu
Agent Event Configuration
On this page, you specify how the SCALANCE X-200 reacts to system events. By selecting
the corresponding check box, you specify how the SCALANCE X-200 reacts to the various
events The following options are available:
The SCALANCE X-200 sends an E-mail.
The SCALANCE X-200 triggers an SNMP trap.
Industrial Ethernet SCALANCE X-100 and SCALANCE X-200 Product Line
Commissioning Manual, 1,
6-21