Technical speci󹪝cations
Current consumption Typically 24 V DC 165 mA
E󹪜ective power loss Typically 24 V DC 4 W
Overvoltage protection at input PTC resettable fuse (0.5 A / 60 V)
Permitted ambient conditions
Ambient temperature During operation -10 ℃ to +60 ℃
During storage -40 ℃ to +80 ℃
During transportation -40 ℃ to +80 ℃
Relative humidity During operation ≤ 95% without condensation
Operating altitude During operation ≤ 2,000 m above sea level at max. +60 °C
ambient temperature
< 3,000 m above sea level at max. +55 °C
ambient temperature
< 4,000 m above sea level at max. +50 °C
ambient temperature
Design, dimensions and weight
Immunity EN 61000-6-2
Emission EN 61000-6-4
Degree of protection IP20
MTBF (EN/IEC 61709; 40 °C) 95 years
Housing material Polycarbonate (plastic)
Weight 205 g
Dimensions (W x H x D) 45 x 100 x 87 mm
Installation options
Mounting on a DIN rail
Wall mounting
Switching properties
Aging time 300 seconds / 45 seconds
1)
Max. number of learnable MAC ad‐
dresses
1024
Response to LLDP frames Blocking
Response to spanning tree BPDU
frames
Forwarding
CoS acc. to IEEE 802.1Q Yes
QoS priority queues 2 / 4
1)
IEEE 802.1Q tags (VLAN ID, priority)
transparent forwarding
Yes
Maximum frame size 1536 bytes
Forwarding of PRP frames (Parallel Re‐
dundancy Protocol)
Yes
Technical speci󹪝cations
8.4 SCALANCE XB004-2LD
SCALANCE XB-000
Operating Instructions, 01/2022, A2B00077300-11 65

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Siemens SCALANCE XB-000 and is the answer not in the manual?

Siemens SCALANCE XB-000 Specifications

General IconGeneral
BrandSiemens
ModelSCALANCE XB-000
CategoryNetwork Router
LanguageEnglish

Related product manuals