Connecting up
4.3 Serial interface
SCALANCE XB-200
Operating Instructions, 09/2015, C79000-G8976-C359-03
27
4.3
Serial interface
Information on the serial interface
Via the serial interface (RJ-11 jack), you can access the CLI of the device directly via an
RS-232 connection (115200 8N1) without assigning an IP address.
Access to the device is also possible independent of the Ethernet ports.
To connect the serial interface to the PC, you require a cable with an RJ-11 plug and 9-
pin D-sub female connector. You can order the connecting cable for the serial interface
as an accessory.
Position and assignment
Figure 4-2 Position and pin assignment of the serial interface (RJ-11 jack), for example on the
SCALANCE XB213-3
Assignment of the terminal block
The connecting cable listed in the "Accessories" section has the following pin assignment:
Contact
Pin assignment of the RJ-11 plug
Pin assignment of the D-sub female con-
nector
1 - -
2
-
TD (Transmit Data)
3 TD (Transmit Data) RD (Receive Data)
4
SG (Signal Ground)
-
5
RD (Receive Data)
SG (Signal Ground)
6
-
-
7
-
8
-
9
-