EasyManua.ls Logo

Siemens SCALANCE XB-200 - Page 30

Siemens SCALANCE XB-200
62 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
Upkeep and maintenance
5.1 Downloading new firmware using TFTP without WBM and CLI
SCALANCE XB-200
30 Operating Instructions, 09/2015, C79000-G8976-C359-03
7. Open a Windows command prompt and change to the directory where the file with the
new firmware is located and then execute the following command :
tftp -i <IP address> put <firmware file>
Note
You can enable TFTP in Microsoft Windows as follows:
"Control Panel" > "Programs and Features" > "Turn Windows features on or off" > "TFTP
Client".
8. Once the firmware has been transferred completely to the device and validated, there is
an automatic restart on the device. This may take several minutes.

Other manuals for Siemens SCALANCE XB-200

Related product manuals