EasyManua.ls Logo

Siemens SCALANCE XB-200 - Page 59

Siemens SCALANCE XB-200
62 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
Approvals
SCALANCE XB-200
Operating Instructions, 09/2015, C79000-G8976-C359-03
59
FDA and IEC marks
The following devices meet the FDA and IEC requirements listed below:
Device
CLASS 1 LASER Product
CLASS 1 LED Product
SCALANCE XB208
-
-
SCALANCE XB205-3 (SC) -
SCALANCE XB205-3LD (SC)
-
SCALANCE XB205-3
-
SCALANCE XB216
-
-
SCALANCE XB213-3 (SC)
-
SCALANCE XB213-3LD (SC)
-
SCALANCE XB213-3
-
Figure A-1 FDA and IEC approvals
CAUTION
Use of controls or adjustments or performance of procedures other than those specified
herein may result in hazardous radiation exposure.
Mechanical stability (in operation)
Device
IEC 60068-2-27 shock
IEC 60068-2-6 vibration
15 g, 11 ms duration
6 shocks per axis
10 - 58 Hz: 0.075 mm
85 - 150 Hz: 1 g
1 octave/min, 20 sweeps
SCALANCE XB208
SCALANCE XB205-3
SCALANCE XB205-3 (LD)
SCALANCE XB205-3 (ST)
SCALANCE XB216
SCALANCE XB213-3
SCALANCE XB213-3 (LD)
SCALANCE XB213-3 (ST)

Other manuals for Siemens SCALANCE XB-200

Related product manuals