EasyManuals Logo

Siemens SIMATIC CP 340 User Manual

Siemens SIMATIC CP 340
200 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Page #74 background imageLoading...
Page #74 background image
Basic Principles of Serial Data Transmission
2.7 Parameterization Data
PtP coupling and configuration of CP 340
74 Manual, 04/2011, A5E00369892-03
X27 (RS 422/485) interface
You will find a description of the parameters for the X27 (RS 422/485) interface in the table
below.
Table 2- 13 X27 (RS 422/485) interface (ASCII driver)
Parameter Description Range of values Default value
Receive line initial state R(A)5V/R(B)0V: This initial
state supports BREAK
detection; it cannot be
deactivated.
R(A)0V/R(B)5V: This initial
state does not support break
detection.
R(A) 5V / R(B) 0V
R(A) 0V / R(B) 5V
R(A) 5V/R(B) 0V
Page layout
The table below contains a description of the parameters for the page layout.
Table 2- 14 Page layout (printer driver)
Parameter Description Range of values Default value
Left margin (number of
characters)
Number of spaces to
precede each line in the
body of the text, header or
footer. It is up to you to
ensure that a line is not too
long for the printer.
0 to 255 3
Lines per page (with header
and footer)
Number of lines to be printed
on each page. The number
of lines printed is calculated
on the basis of the
separators output. In other
words, all headers and
footers must be counted.
1 to 255
0 (continuous printing)
50

Table of Contents

Other manuals for Siemens SIMATIC CP 340

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Siemens SIMATIC CP 340 and is the answer not in the manual?

Siemens SIMATIC CP 340 Specifications

General IconGeneral
BrandSiemens
ModelSIMATIC CP 340
CategoryComputer Hardware
LanguageEnglish

Related product manuals