16-2
Equipment
Manual OP7, OP17
Release 04/99
The
OP7 is available in versions PP
, DP and DP-12. The versions dif
fer only
in as far as their communication options are concerned (refer to table 16-1).
Figure 16-1 shows the connection elements on the underside of the OP7.
IF 1B
IF 1A
Figure 16-1 Locations of the Connection Elements on the Underside of the OP7
Table 16-1 Communication Options Featured by Different OP7 Versions
Connections OP7
PP DP DP-12
SIMATIC
S5
– AS51
1 (TTY)
– F
AP (TTY/RS232)
– PROFIBUS-DP up to 1.5 MBd
– PROFIBUS-DP up to 12 MBd
IF 1A
IF 1A
—
—
—
—
IF 1B
—
IF 1A
IF 1A
IF 1B
IF 1B
SIMA
TIC S7/M7
– PPI
– MPI
– PROFIBUS-DP up to 1.5 MBd
– PROFIBUS-DP up to 12 MBd
—
—
—
—
IF 1B
IF 1B
IF 1B
—
IF 1B
IF 1B
IF 1B
IF 1B
SIMA
TIC 500/505
– RS232
– RS422/RS485
IF 1A
IF 1B
—
—
IF 1A
IF 1B
Other PLCs
– RS232/TTY
– RS422/RS485
IF 1A
IF 1B
—
—
IF 1A
IF 1B
PC/PU (TTY)
IF 1A
—
IF 1A
PC/PU (RS232)
IF 1A IF 1A IF 1A
Printer (TTY)
IF 1A
—
IF 1A
Printer (RS232)
IF 1A IF 1A IF 1A
Connection
elements