B-8
Equipment
Manual OP7, OP17
Release 04/99
Remedy:CauseMes-
sage
397 The
part program specified does not exist.
The record specified does not exist.
The PLC specified (FM or NC) is not ready
.
398
The command cannot be executed in the MCU
mode selected.
The command is not supported by the MCU ver
-
sion.
399
The PLC does not have a directory of tool correc
-
tions.
The tool correction specified does not exist.
400
Illegal key pressed.
401 V
alue entered could not be converted.
402
Operator error on ST
A
TUS V
AR or FORCE V
AR
screen:
only 10 entries are permitted (after
pressing INS if 10th line already
used).
403
Incorrect time entered
404
Incorrect date entered
406
Operator error on ST
A
TUS V
AR or FORCE V
AR
screen
V
alues can only be changed after up
-
date operation has been cancelled
(BREAK key).
407 Y
ou have attempted to delete the only data record
for a recipe.
409
Lower limit violated: you have attempted to enter
a setpoint that is below the configured lower li
-
mit.
Enter a value that is greater than or
equal to the specified value. No limit
is indicated for data of the type
DOUBLE.
410
Upper limit violated: you have attempted to enter
a setpoint that is above the configured upper li
-
mit.
Enter a value that is less than or
equal to the specified value. No limit
is indicated for data of the type
DOUBLE.
411
Illegal screen selection because incorrect PLC
type specified (external driver)
Change configured interface
parameter.
500...
503
Scheduler
, counter
, date or time data can not be
sent.
This error can occur if the PLC is
temporarily overloaded or if the
f i bl ki i k df
504
Free ASCII Protocol: operator input value could
not be sent.
py
function block is not invoked for
more than 1.5 s.
505
The data record can not be sent as the recipe disa
-
ble bit on the PLC is set or because transfer of a
recipe is still in progress.
T
ry sending again later when the
PLC has released the recipe mailbox.
506
Overload: too many message blocks with the
same block number in transit.
This error occurs if the PLC sends
too many jobs using ’collect message
area’ within a certain period of time.

Table of Contents

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Siemens simatic hmi op7 and is the answer not in the manual?

Siemens simatic hmi op7 Specifications

General IconGeneral
BrandSiemens
Modelsimatic hmi op7
CategoryControl Panel
LanguageEnglish

Related product manuals