Commissioning the device
4.3 Parameter assignment for Comfort Panel
Comfort Panels
144 Operating Instructions, 07/2017, A5E36770603-AB
The following messages can be displayed in the "Load Preview" dialog:
– Alarms of type "Information":
Info
Firmware version ...
Firmware and Runtime version on the HMI
Info Ready For Loading Project data is suitable for the HMI device
– Alarms of type "Warning" with options:
Overwrite Select project data
The following lines contain options for
overwriting data on the HMI device.
Recipes
Overwrite recipes of the HMI device with the
recipes of the project (optional).
data
Overwrite the user administration on the HMI
device with the user administration of the
Upgrade Runtime upgrade
Runtime version on the HMI device is older
than the Runtime version of the project,
versions are compatible, upgrade of Runtime
version on the HMI device is optional.
Upgrade Firmware upgrade Firmware version on the HMI device is older
than the firmware version of the project,
versions are compatible, upgrade of firmware
on the HMI device is optional.
Downgrade Runtime
downgrade
Runtime version on the HMI device is newer
than the Runtime version of the project,
versions are compati
ble, downgrade of Runtime
version on the HMI device is optional.
Downgrade Firmware
downgrade
Firmware version on the HMI device is newer
than the firmware version of the project,
versions are compatible, downgrade of
firmware on the HMI device is optional.