6. Assign an IP address to the device using DHCP or SINEC PNI.
7. In a Windows command prompt, go to the directory where the 󹪝le with the new 󹪝rmware is
located and use the following command:
tftp -i <IP address> put <firmware file>.
Note
You can enable TFTP in Microsoft Windows as follows:
"Control Panel" > "Programs and Features" > "Turn Windows features on or o󹪜" > "TFTP Client".
Once the 󹪝rmware has been transferred completely to the device and validated, the device
restarts. This may take a few minutes.
Troubleshooting
8.3Load a 󹪝rmware 󹪝le via TFTP.
SCALANCE XR-300
84 Operating Instructions, 03/2023, C79000-G8976-C586-02