EasyManuals Logo

Siemens SIMATIC NET TeleControl S7-1200 CP 1243-1 User Manual

Siemens SIMATIC NET TeleControl S7-1200 CP 1243-1
112 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Page #64 background imageLoading...
Page #64 background image
Configuration
4.8 Security
CP 1243-1
64 Operating Instructions, 12/2016, C79000-G8976-C365-02
Telecontrol server under "Partner stations" of the CP
You configure the following information here:
Address of the telecontrol server
IP address or name of the telecontrol server that can be resolved by DNS.
Port
Port number of the telecontrol server
Users and roles in the global security settings
1. Open the following page in the project tree:
Global security settings > User management
2. Role
Open the "Roles" tab
The two tables "Roles" and "Rights of the role" become visible.
If necessary open the "Roles view" if this is hidden by the "Rights of the role" table.
In the "Roles" table (at the top) create a new user-defined role for TeleService.
3. In the "User" tab create a user that will later be allowed to execute the TeleService
functions for the CP.
Configure the following parameters:
User name
Assign the name of the user that will have TeleService rights.
You require the user name at the start of a TeleService session.
Authentication method
Select the authentication method "Password" for this user.
Password
Assign the password.
You require the password at the start of a TeleService session.
Note:
You specify the password properties of the security functions in the "Password
policies" tab.
You enter the password on the engineering station when starting a TeleService
session.
Maximum time of the session
The time that can be configured here is only required for access to SCALANCE S
modules. If the user is set up only for TeleService sessions, you can leave the default
value unchanged.
4. Click on the "Roles" tab.
5. Select the CP in the lower list "Rights of the role" under the "Module rights" group.

Table of Contents

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Siemens SIMATIC NET TeleControl S7-1200 CP 1243-1 and is the answer not in the manual?

Siemens SIMATIC NET TeleControl S7-1200 CP 1243-1 Specifications

General IconGeneral
Compatible ControllersS7-1200
InterfaceEthernet
Power Supply24 V DC
Number of Possible Connections8
Mounting TypeDIN rail
Weight200 g
Data Transfer Rate10/100 Mbps
ProtocolsTCP/IP, UDP, DNP3, IEC 60870-5-104
Supply Voltage20.4 ... 28.8 V DC
Current Consumption100 mA
Operating Temperature-20 ... +60 °C

Related product manuals