5 Useful information
Reading out UID with SIMATIC RF1070R
Article ID: 109780625, V1.0, 09/2020
28
© Siemens AG
2020 All rights reserved
Table 5-4 Response telegram with no errors
Byte
Value
Description
0
0x0C
Without checksum
0x1C
With checksum
1
0x00
DevCode of the command set containing the command to be called.
2
0xC7
CmdCode of the command to be called.
3
0x00
Parameter length (0 bytes)
4
0x00
5
0xC6
Optional checksum (when the value "0x1C" is set in byte 0).
vhl_select: Select a card located in the antenna field of the reader
Table 5-5 Job telegram
Byte
Value
Description
0
0x0C
Without checksum
0x1C
With checksum
1
0x01
DevCode of the command set containing the command to be called.
2
0x00
CmdCode of the command to be called.
3
0x04
Parameter length
4
0x00
5
0xFF
Mask for the card type (e.g. 0xFFFF). You can find detailed
information on the card types in manual number \3\.
6
0xFF
7
0x01
Reselect
8
0x00
AllowConfig
9
0xXX
Optional checksum (when the value "0x1C" is set in byte 0)
Table 5-6 Response telegram without errors
Byte
Value
Description
0
0x0C
Without checksum
0x1C
With checksum
1
0x01
DevCode of the command set containing the command to be called.
2
0x00
CmdCode of the command to be called.
3
0x01
Parameter length
4
0x00
5
0x30
Card type
You can find detailed information on the card types in manual number
\3\.
6
0x0D
Optional checksum (when the value "0x1C" is set in byte 0).