2 Engineering of the STEP 7 Program
Reading out UID with SIMATIC RF1070R
Article ID: 109780625, V1.0, 09/2020
9
© Siemens AG
2020 All rights reserved
2.2 Function block "ReadUID"
The "ReadUID" function block contains all functionality for communicating with the
RF1070R reader.
The "ReadUID" function block is a custom development for this application
example and is already integrated in the STEP 7 project so that you can adapt it to
your requirements. It is called cyclically in OB1 and automatically automatically
calls the point-to-point instructions "Port_Config", "Send_P2P" and "Receive_P2P".
Function
Function block "ReadUID" realizes
the configuration of the CM1241 RS232 communication module
the initialization of the RF1070R reader
monitoring of the RF1070R reader's antenna field
selection of the card located in the antenna field
receipt and analysis of the UID
output of status and error messages from the block.
This functionality is implemented as a simple sequencer with the following states: