EasyManua.ls Logo

Siemens SIMATIC RF660M - Page 43

Siemens SIMATIC RF660M
72 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
"SIMATIC Mobile Reader" app
5.4 Functions
Mobile reader SIMATIC RF660M
Operating Instructions, 02/2022, C79000-G8976-C660-01
43
Table 5- 4 Functions of the "Write" tab
Functions/
parameter
Description
Target tag
The EPC ID of the selected target transponder is displayed in this area.
Password
Input box for the Access password
If the transponder is password-protected, you need to enter the Access password
here to be able to write the data to the selected memory area of the target
transponder.
Memory area
Drop-down list to select the memory area within which you want to change or
write the data of the target transponder.
Format
Drop-down list to select the input format of the data to be written.
DEC
Decimal input format. Numbers from 0 ... 255 are allowed.
HEX
Hexadecimal input format. Hyphens are entered automatically.
ASCII6
ASCII6 input format. All characters compliant with VDA 5500 are allowed.
ASCII8
ASCII8 input format. All ASCII characters are allowed.
Start (bytes)
Drop-down list to select the start address of the memory area in bytes from
which you want to change or write the data of the target transponder.
Maximum permissible start address: 255 bytes
Length (bytes)
Drop-down list to select the length of the memory area in bytes within which you
want to change or write the data of the target transponder.
Maximum permissible length: 63 bytes
Data to be
written
Input box in which you can enter the data or the text that you want to write to
the selected memory area of the target transponder.
Note: Note that it is possible in principle to enter in this box data of a length that
differs from the information in the "Length (bytes)" box.
If less data is entered than specified in the "Length (bytes)" box and you click the
"Write" button, this data is written. All other data is retained.
If more data is entered than specified in the "Length (bytes)" box, it is highlighted
in color. In this case, the data cannot be written.
Write
Button to execute the write operation

Related product manuals