"SIMATIC Mobile Reader" app
5.4 Functions
Mobile reader SIMATIC RF660M
Operating Instructions, 02/2022, C79000-G8976-C660-01
45
Table 5- 5 Functions of the "Read" tab
Functions/
parameter
Description
Target tag
The EPC ID of the selected target transponder is displayed in this area.
Password
Input box for the Access password
If the transponder is password-protected, you need to enter the Access password
here to be able to read the data from the selected memory area of the target
transponder.
Memory area
Drop-down list to select the memory area from which you want to read the data
of the target transponder.
Format
Drop-down list to select the output format of the data to be read.
DEC
Decimal input format. Numbers from 0 ... 255 are allowed.
HEX
Hexadecimal input format. Hyphens are entered automatically.
ASCII6
ASCII6 input format. All characters compliant with VDA 5500 are allowed.
ASCII8
ASCII8 input format. All ASCII characters are allowed.
Start (bytes)
Drop-down list to select the start address of the memory area in bytes from
which you want to read the data of the target transponder.
Maximum permissible start address: 255 bytes
Length (bytes)
Drop-down list to select the length of the memory area in bytes within which you
want to read the data of the target transponder.
Maximum permissible length: 63 bytes
Tag data of the
selected
memory bank
Output field showing the data or text that you read out from the selected
memory area of the target transponder.
Read
Button to execute the read operation.