Readers
5.2 SIMATIC RF615R
SIMATIC RF600
System Manual, 11/2018, J31069-D0171-U001-A21-7618
113
Typical transmission time per byte
• Write access • 2 ms
• Read access • 0.15 ms
2)
Maximum permitted current consumption
Maximum permitted current consumption via
the digital I/O interface
0.5 A (< 20 °C; 0.33 A at 55 °C)
Current consumption (on standby), typical
• 20 V input voltage on the reader • 200 mA / 4 W
• 24 V input voltage on the reader • 170 mA / 4.1 W
• 30 V input voltage on the reader • 150 mA / 4.2 W
Current consumption (at 400 mW transmit power), typical
• 20 V input voltage on the reader • 260 mA / 5.2 W
• 24 V input voltage on the reader • 220 mA / 5.3 W
• 30 V input voltage on the reader • 170 mA / 5.1 W
Mechanical specifications
Permitted ambient conditions
Ambient temperature
• During operation • -25 ... +55 °C
• During transportation and storage • -40 ... +85 °C