EasyManua.ls Logo

Siemens SIMATIC RF680R - Page 137

Siemens SIMATIC RF680R
490 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
Readers
5.3 SIMATIC RF650R
SIMATIC RF600
System Manual, 11/2018, J31069-D0171-U001-A21-7618
137
6GT2811-6AB20-xAA0
Channel spacing
ETSI 600 kHz
FCC 500 kHz
CMIIT 250 kHz
ARIB (STD-T107) 200 kHz
Modulation methods ASK: DSB modulation & PR-ASK modulation
encoding, Manchester or Pulse Interval (PIE)
Multitag capability
Yes
Typical transmission time per byte
Write access 2 ms
Read access 0.15 ms
Supply voltage
24 V DC (20 ... 30 V DC)
2)
Maximum permitted current consumption
2 A
Maximum permitted current consumption via
the digital I/O interface
1 A
Current consumption (on standby), typical
20 V input voltage on the reader 220 mA / 4.4 W
24 V input voltage on the reader 190 mA / 4.5 W
30 V input voltage on the reader 150 mA / 4.5 W
Current consumption (at 1000 mW transmit power), typical
20 V input voltage on the reader 450 mA / 9.0 W
24 V input voltage on the reader 370 mA / 8.9 W
30 V input voltage on the reader 300 mA / 9.0 W
Current consumption (at 2000 mW transmit power), typical
20 V input voltage on the reader 610 mA / 12.2 W
24 V input voltage on the reader 500 mA / 12.0 W
30 V input voltage on the reader 410 mA / 12.3 W
Interfaces
Antenna connectors
4x RP-TNC
Power supply
1x RS422, M12 (8-pin)
Digital I/O interface
1x M12 (12-pin)
Digital inputs
4
Digital outputs
4
Ethernet interface
1x RJ45 (8-pin), 100 Mbps

Table of Contents